Tosylimidazole

SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
CATALOG No.:40173
MSDS Name:Tosylimidazole
Synonyms:1-(p-Toluenesulfonyl)imidazole
Company Identification: Shanghai Medpep Co., Ltd.
For information, Call: +86 21 65566949

SECTION 2. COMPOSITION/INFORMATION ON INGREDIENTS
Hazard Component: Tosylimidazole
Purity: 99% min.
CAS No:2232-08-8
Molecular Formula: C10H10N2O2S
Molecular Weight: 222.26

SECTION 3. HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
Warning! Causes respiratory tract irritation. Irritant. Causes eye and skin irritation. May cause digestive tract irritation.

TARGET ORGANS: Not available.
POTENTIAL HEALTH EFFECTS
EYES:
- Causes eye irritation. May cause chemical conjunctivitis.

SKIN
Causes skin irritation.

INGESTION
May cause gastrointestinal irritation with nausea, vomiting and diarrhea.

INHALATION
Causes respiratory tract irritation. Can produce delayed pulmonary edema.

CHRONIC:
Effects may be delayed.

SECTION 4. FIRST-AID MEASURES
EYES:
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid imme diately.
SKIN
Get medical aid. Flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse.
INGESTION:
Never give anything by mouth to an unconscious person. Get medical aid. Do NOT induce vomiting. If conscious and alert, rinse mouth and drink 2-4 cupfuls of milk or water.
INHALATION
Get medical aid immediately. Remove from exposure and move to fresh air immediately. If breathing is difficult, give oxygen. Do NOT use mouth-to-mouth resuscitation. If breathing has ceased apply artificial respiration using oxygen and a suitable mechanical device such as a bag and a mask.
NOTES FOR PHYSICIAN
Treat symptomatically and supportively.

SECTION 5. FIRE FIGHTING MEASURES
FLAMMABILITY: Not available.
FLASH POINT:Not available
.
AUTOIGNITION TEMPERATURE: Not available.
EXPLOSION LIMITS, LOWER: Not available.
EXPLOSION LIMITS, UPPER: Not available.
EXTINGUISHING MEDIA

Use agent most appropriate to extinguish fire. Use water spray, dry chemical, carbon dioxide, or appropriate foam.
GENERAL INFORMATION:As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Runoff from fire control or dilution water may cause pollution.

SECTION 6. ACCIDENTAL RELEASE MEASURES
General Information:

Use proper personal protective equipment as indicated in Section 8.
SPILLS AND LEAKS:

Vacuum or sweep up material and place into a suitable disposal container. Clean up spills immediately, observing precautions in the Protective Equipment section. Avoid generating dusty conditions. Provide ventilation.
ENVIRONMENTAL PRECAUTIONS: No data.

SECTION 7. HANDLING AND STORAGE
HANDLING
Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Minimize dust generation and accumulation. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use with adequate ventilation.
STORAGE
Keep container closed when not in use. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances.
HYGIENE PRACTICES
No data.

SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
ENGINEERING CONTROLS
Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. Use adequate ventilation to keep airborne concentrations low.
EYES:

Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166.
SKIN AND CLOTHING:

Wear appropriate protective gloves to prevent skin exposure. Wear appropriate protective clothing to minimize contact with skin.
RESPIRATORS:

Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced.
OTHER PROTECTIVE
No data.

SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE:: White Crystalline powder.
ODOR: Not available.
pH: Not available.
VAPOR PRESSURE: Not available.
VISCOSITY: Not available.
BOILING POINT: Not available.
Freezing/Melting Point: 78.00 - 79.00 °C
Decomposition Temperature: Not available.
Solubility: Not available.

Specific Gravity/Density: Not available.

SECTION 10. STABILITY AND REACTIVITY
CHEMICAL STABILITY: Stable at room temperature in closed containers under normal storage and handling conditions.

CONDITIONS TO AVOID: Incompatible materials, dust generation, excess heat, strong oxidants.
INCOMPATIBILITY WITH OTHER MATERIALS:Oxidizing agents, strong acids.
HAZARDOUS DECOMPOSITION PRODUCTS: Nitrogen oxides, carbon monoxide, irritating and toxic fumes and gases, carbon dioxide, nitrogen, sulfur oxides (SOx), including sulfur oxide and sulfur dioxide.

HAZARDOUS POLYMERIZATION: Has not been reported

SECTION 11. TOXICOLOGICAL INFORMATION
RTECS #:

OTHER TOXICOLOGICAL INFORMATION: Not available.

SECTION 12. ECOLOGICAL INFORMATION
No information available.

SECTION 13. DISPOSAL CONSIDERATIONS
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.

SECTION 14. TRANSPORT INFORMATION
Not regulated as a hazardous material no matter in the USA or Canada.

SECTION 15. REGULATORY INFORMATION
Chinese Governmental regulations。

SECTION 16. OTHER INFORMATION
LAST UPDATED:2007,10,10
THE INFORMATION ABOVE IS BELIEVED TO BE ACCURATE AND REPRESENTS THE BEST INFORMATION CURRENTLY AVAILABLE TO US. HOWEVER, WE MAKE NO WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WITH RESPECT TO SUCH INFORMATION, AND WE ASSUME NO LIABILITY RESULTING FROM ITS USE. USERS SHOULD MAKE THEIR OWN INVESTIGATIONS TO DETERMINE THE SUITABILITY OF THE INFORMATION FOR THEIR PARTICULAR PURPOSES. IN NO EVENT SHALL CII BE LIABLE FOR ANY CLAIMS, LOSSES, OR DAMAGES OF ANY THIRD PARTY OR FOR LOST PROFITS OR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES, HOWSOEVER ARISING, EVEN IF CII HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.


 
Shanghai Medpep Co., Ltd.All rights reserved. Copyright 2007.